Florence DANEDE
Engineer in material sciences and characterization
Bâtiment P5 - 227
Unité Matériaux et Transformations
Cité scientifique, Bât. P5
Université de Lille
59655 Villeneuve d'Ascq
France
Tel: +33 (0)3 20 43 47 08
Fax: +33 (0)3 20 43 40 84
Email
: Send an email to Florence DANEDE
ORCID Identifier
: 0000-0001-5139-9187
Unité Matériaux et Transformations
Cité scientifique, Bât. P5
Université de Lille
59655 Villeneuve d'Ascq
France
Tel: +33 (0)3 20 43 47 08
Fax: +33 (0)3 20 43 40 84
ORCID Identifier
Research team: Matériaux moléculaires et thérapeutiques
Activity
Powder X-Ray diffraction Thermal analysis (DSC, modulated DSC, TGA) Samples preparation Competent person in radioprotection
Warning: getimagesize(..//Instruments/ImagesDB/s_img-183-2074642610.jpg): failed to open stream: No such file or directory in /var/www/html/Private/Instruments/show.inc.php on line 47

ATG Q500 (TA Instruments)
Research team: Matériaux moléculaires et thérapeutiques.
Contact: Florence DANEDE.
Characterization of solvent losses and degradations in molecular materialsTemperature range: from 30 ° C to 550 ° C
Warning: getimagesize(..//Instruments/ImagesDB/s_img-185-1577153651.jpg): failed to open stream: No such file or directory in /var/www/html/Private/Instruments/show.inc.php on line 47

X-ray diffractometer on powders, X'Pert Pro (Panalytical)
Research team: Matériaux moléculaires et thérapeutiques.
Platform: Plateau d’analyses par diffraction des Rayons X.
Contacts: Mathieu GUERAIN, Florence DANEDE.
Study of the structural organization of molecular materials: vitreous states and phase transformations induced by external stresses (temperature variations, grinding, aging, ...)
Technical characteristics
Technical characteristics
- Copper tube
- Transmission measurements on samples conditioned in capillaries with the possibility of varying the temperature from ambient to 300 ° C (Huber oven)
- Reflection measurements on platelets with the possibility of varying the temperature from -150 ° C to 400 ° C (room Anton Paar TTK 450)
Instruments in charge
ATG Q500 (TA Instruments), X-ray diffractometer on powders, X'Pert Pro (Panalytical)Warning: count(): Parameter must be an array or an object that implements Countable in /var/www/html/Private/LillOA/func-LillOA.php on line 902
Warning: count(): Parameter must be an array or an object that implements Countable in /var/www/html/Private/LillOA/func-LillOA.php on line 1245
Warning: count(): Parameter must be an array or an object that implements Countable in /var/www/html/Private/LillOA/func-LillOA.php on line 775
Warning: count(): Parameter must be an array or an object that implements Countable in /var/www/html/Private/LillOA/func-LillOA.php on line 714